Fujitsu MBC2073RC Manual Do Utilizador

Página de 439
Parameter Data Format 
 
5.2.8  Start-Stop Cycle Counter Page (X'0E')  
Table 5.49  Start-stop cycle counter page (X'0E') 
 Bit 
Byte 
7 6 5 4 3 2 1 0 
0 0 0 0 1 1 1 0 
1 X'00' 
(Reserved) 
Page Length (MSB) 
Page Length (LSB) 
 
All of the following parameters have this header. 
Page Length will be defined based on the value of Parameter Pointer.  (CDB 5-6) 
•  Date of manufacture (page 0E, code 0001)  
Table 5.50  Date of manufacture (page 0E, code 0001) 
 Bit 
Byte 
7 6 5 4 3 2 1 0 
(MSB) 
 
X'0001' (Parameter code) 
 
(Date of Manufacture) 
(LSB) 
DU DS TSD
ETC
TMC  LBIN LP 
0 1 0 0 0 0 0 1 
X'06' (Parameter Length) 
8 (MSB) 
10 
Year of manufacture (4 ASCII characters) 
11 (LSB) 
12 
13 
(MSB) 
 
Week of manufacture (2 ASCII characters) 
  
(LSB) 
The year and week in the year that the device was manufactured shall be set in the 
parameter field defined by parameter code 0001h.  The date of manufacture shall 
not be savable by the INIT using the LOG SELECT command.  The date is 
expressed in numeric ASCII characters (30h-39h) in the form YYYYWW, as 
shown above. 
 
344 
C141-C013