1.6   Transport layer 
 
C141-C013 
81 
If necessary, fill bytes are placed after the INFORMATION UNIT field so that the 
CRC field is aligned on a four-byte boundary.  The number of the fill bytes is 
specified by the NUMBER OF FILL BYTES field.  If the transferred bytes in the 
last DATA frame are not aligned on a four byte boundary, this field is set to the 
number of the extra bytes (4 - the remainder of (the number of transferred bytes/4) 
bytes). 
The CRC field contains a CRC value that is computed over the entire SSP frame 
prior to the CRC field including the fill bytes (i.e., all data dwords between the 
SOF and EOF).  
Drives ignore the Reserved fields. 
1.6.2  Information units  
1.6.2.1 
COMMAND information unit  
Table 1.34 defines the command IU. The COMMAND frame is sent by an SSP 
INIT port to request that a command be processed by the device server in a logical 
unit. 
Table 1.34  COMMAND information unit  
Bit 
Byte 
(MSB) 
 
 
LOGICAL UNIT NUMBER 
(LSB) 
Reserved 
ENABLE 
FIRST 
BURST 
Reserved 
TASK ATTRIBUTE 
10 
Reserved 
11 
ADDITIONAL CDB LENGTH  
(n dwords) 
Reserved 
12 
(MSB) 
 
27 
 
CDB 
(LSB) 
28 
27+ n x 4 
ADDITIONAL CDB BYTES 
 
The LOGICAL UNIT NUMBER field contains the address of the logical unit. 
An ENABLE FIRST BURST bit set to "1" specifies that the first burst data item 
is transferred as defined by the FIRST BURST SIZE field in the Disconnect-
Reconnect mode page.  However, drives do not support this bit.  Therefore, a 
drive ignores the FIRST BURST SIZE field of the Disconnect-Reconnect mode 
page. 
Table 1.35 contains the definitions of the TASK ATTRIBUTE field.  However, 
drives do not support ACA in Table 1.35.  Moreover, when a reserved TASK