Specifications 
24 
C141-E252 
Table 2.3 
Environmental/Power requirements (2/2) 
Specification 
Item 
MBA3300RC MBA3174RC MBA3073RC 
Power 
requirement 
(*5) 
Ripple (+5V, +12V) 
250mVp-p or less (*7) 
 
(*1) 
For detail condition, see Section 4.1. 
(*2) 
Vibration applied to the HDD is measured at near the mounting screw hole on the frame as much as 
possible. 
(*3) 
At random seek write/read and default on retry setting with log sweep vibration. 
(*4) 
At power-off state after installation 
(*5) 
Input voltages are specified at the HDD connector side, during HDD Idle state. 
(*6) 
Operating currents are values under random W/R operation of full partition at about 220 IOPS. 
(*7) 
High frequency noise (over 20MHz) is less than 100 mVp-p. 
 
2.1.4 Error 
rate 
 
Errors detected during initialization and replaced by alternate block assignments are not included in 
the error rate.  Data blocks to be accessed should be distributed over the disk equally. 
 
(1) 
Unrecoverable error rate 
 
Errors which cannot be recovered within 63 retries and ECC correction should not exceed 10 per 10
16
 
bits read. 
 
(2) 
Positioning error rate 
 
Positioning errors which can be recovered by one retry should be 10 or less per 10
8
 seeks. 
 
2.1.5 Reliability 
(1) 
Mean Time Between Failures (MTBF) 
 
MTBF of the HDDs during their life time is 1,400,000 hours (operating:  24 hours/day, 7 days/week 
average DE surface temperature: 50°C or less).  Continual or sustained operation at case DE surface 
temperature above 50°C may degrade product reliability.