Fujitsu MCM3130SS Manual Do Utilizador

Página de 170
SCSI BUS 
 
7-12 C156-E228-02EN 
(2) Termination circuit 
The termination circuit is a resistor termination as shown in Figure 7.8.  The 
termination circuits are installed in SCSI devices which are connected at both ends 
of the interface cable. 
TERMPWR
or +5 VDC
V
IN
2.6V
Generater
Resistor
110
Ω
, 0.5%
R
2
R
3
R
18
–SCSI LINE 18
–SCSI LINE 3
–SCSI LINE 2
–SCSI LINE 1
 
Figure 7.8  SCSI termination circuit 
7.4.2  Power supply for terminating resistor 
The TERMPWR signal on the interface connector is used to supply power to the 
terminating resistor circuit connected to both ends of the cable.  In a system 
configuration where the terminating resistor is installed outside the SCSI device or 
if there is a possibility of the power to the SCSI device with the terminating 
resistor being cut off, power for the terminating resistor must be supplied to the 
TERMPWR line from an SCSI device on the bus.  The SCSI device always 
working as an INIT (example:  host adapter) should supply that power. Power 
must be supplied to the TERMPWR line through a diode or other element to 
prevent reverse current. 
Table 7.3 lists the requirements for terminating the resistor power supply (V
term
Table 7.3  Requirements for terminating resistor power supply 
Item Single-ended 
type 
Output voltage 
4.25 to 5.25 VDC 
Current capacity 
900 mA min. 
Sink current 
1.0 mA max.