Fujitsu MCM3130SS Manual Do Utilizador

Página de 170
Installation Requirements 
3-2 C156-E228-02EN 
(b)  IC (controller, read Amp) 
IC (controller)
IC (read Am p)
 
Figure 3.1  Surface temperature measurement point (2 of 2) 
3.1.2 Temperature requirements 
Table 3.1 shows the temperature requirement at the measurement point shown in 
Figure 3.1. 
Table 3.1  Temperature requirements at measurement points 
Measurement point 
Maximum allowable surface temperature 
Inside the cartridge 
55°C (*1) 
IC (controller) surface  
85°C 
IC (read Amp.) surface 
85°C 
*1 
60°C for the optical disk cartridges recommended by Fujitsu (except 1.3 
GB). 
The following describes a procedure for measuring the temperature inside a 
cartridge. 
1)  At the bottom of the cartridge, open a hole large enough for the thermocouple 
to be inserted as shown in Figure 3.1. 
2)  Disassemble the cartridge.