Fujitsu MCM3130SS Manual Do Utilizador

Página de 170
Installation Requirements 
3-20 C156-E228-02EN 
Table 3.3  Recommended components for connection 
Category Name  Model 
Manufacturer 
Symbol 
in 
Figure 3.15 
Cable socket 
(closed-end type) 
FCN-707B050-AU/B Fujitsu 
Ltd. 
Cable socket 
(through-end type) 
FCN-707B050-AU/O Fujitsu 
Ltd. 
S01 
UL20184-
LT25PX28AWG 
Hitachi Cable, Ltd. 
SCSI cable 
Signal cable 
455-248-50 SPECTRA-STRIP 
— 
Housing for cable 
socket 
1-480424-0 AMP 
Contact 170121-4  AMP 
S2 
Power supply cable 
Cable AWG18 
— — 
Housing for cable 
socket 
LPC-16F02 Honda-Tsushin 
Receptacle LPC-F104N  Honda-Tsushin 
SH2 
External operator panel 
Cable AWG28 
— — 
 
(1) SCSI cable 
A terminating resistor is mounted on the drive when the drive is shipped.  A 
terminating resistor must be disconnected when the drive is not connected to an 
end of the SCSI cable.  Select a method of power supply to the terminating resistor 
circuit according to the setting pins on the drive.  See Section 4.2 for details. 
(2) Power supply cable 
The drive must be star-chain-connected to the DC power supply unit (one-to-one 
connection) to reduce the influence of load variations. 
3.4.3  External operator panel 
Some set switch settings can be manipulated through the external operator panel 
interface. 
Figure 3.16 shows a recommended circuit for the external operator panel.  Since 
an external operator panel is not provided as an option, the user must design one 
based on the system requirements and the recommended circuit.