Fujitsu MCE3130AP Manual Do Utilizador

Página de 175
C156-E142-02EN
2 - 7
2.1.3
Environmental and power requirements
Table 2.3 lists the environmental and power requirements.
Table 2.3
Environmental and power requirements (1 of 2)
Item
Specification
Power
requirements
Average
+5 VDC±5%,  1.1 A (2.5 A Max.) (*1)
Ripple requirement 100mV P-P (DC-1 MHz)
MCE3130AP
MCE3064AP, MCF3064AP
Ready
3.9 W (typical) (*2)
3.9 W (typical) (*2)
Random seek, read/ or write
5.5 W (typical) (*2)
5.3 W (typical) (*2)
Power save mode
  Pre-idle mode
  Idle mode
  Standby mode
  Sleep mode
3.40 W (typical) (*2)
2.00 W (typical) (*2)
0.65 W (typical) (*2)
0.65 W (typical) (*2)
3.40 W (typical) (*2)
2.00 W (typical) (*2)
0.65 W (typical) (*2)
0.65 W (typical) (*2)
With panel
101.6
"150.0"25.4 mm
Without panel
101.6
"148.4"25.4 mm
Weight
480 g (with panel)
Environmental
requirements
Operating
Temperature:            5 to 45°C (*3)
                                (gradient 15°C /h or less)
Relative humidity:  10 to 85% (Noncondensing)
Max. wet bulb temperature:    29°C or lower
Idle
Temperature:            0 to 50°C
Relative humidity:  10 to 85% (Noncondensing)
Max. wet bulb temperature:    36°C or lower
Transport
Temperature:     –40 to 60°C (24 hours or less)
Temperature:     –20 to 60°C (24 hours or more)
Relative humidity:  5 to 90% (Noncondensing)
Max. wet bulb temperature:    41°C or lower
Requirement:  Packing conditions specified by Fujitsu
Installation
Tilt angle
–5° to +10° (*3)
Vibration/
shock
Operating
           3.92 m/s
2
 (0.4 G [5 to 500 Hz, sine sweep])
Shock 19.6 m/s
2
 (2 G [10ms, half-sine pulse])
Idle
No cartridge, power ON
           9.8 m/s
2
 (1.0 G [5 to 500 Hz, sine sweep])
Shock 49 m/s
2
 (5 G [10 ms, half-sine pulse])
Transport
Shock 490 m/s
2
 (50 G [10 ms, half-sine pulse])
Requirement:  Packing conditions specified by Fujitsu
Power
consumption
Dimensions
(W
"D"H)