4.3.3 
Cable connector requirements 
 
Table 4.2 lists the recommended components cable connection. 
Table 4.2  Recommended components for connection 
Applicable 
model 
Type Name 
Part number 
(Size) 
Manufacturer 
Reference
(*1) 
787311-4 
Tyco Electronics 
AMP 
NC 
SCSI connector 
(CN1) 
Connector 
71743-1085 Molex 
 
DHJ-PAC68-2AN-
FG 
Fujikura 
Cable socket 
(closed-end type) 
5786090-7 
Tyco Electronics 
AMP 
SCSI cable (CN1) 
Signal cable 
UL20528-FRX- 
68-P0.635 
Fujikura 
S1 
Cable socket housing  1-480424-0 
Tyco Electronics 
AMP 
Contact 170148-1 
Tyco Electronics 
AMP 
Power supply 
cable (CN1) 
Cable 
(AWG18 to 24) 
 
S2 
Cable socket housing  A3B-12D-2C 
HIROSE 
ELECTRIC 
Contact A3B-2630SCC 
HIROSE 
ELECTRIC  
External operator 
panel (CN1) 
Cable 
(AWG26 to 36) 
 
S3 
Cable socket housing  FCN-723J024/2M 
FUJITSU 
TAKAMIZAWA 
Contact FCN-723J-G/AM 
FUJITSU 
TAKAMIZAWA 
NP 
External operator 
panel (CN2) 
Cable (AWG28) 
 
S4 
 (*1)  See Figure 4.22. 
 
(1) SCSI 
cable 
 
Refer to Section 1.3 “Physical Requirements” and Section 1.4 “Electrical Requirements” of the 
SCSI Physical Interface Specifications. 
(2) Power 
cable 
 
HDDs must be star-connected to the DC power supply (one to one connection) to reduce the 
influence of load variations. 
(3) DC 
ground 
 
The DC ground cable must always be connected to the HDD because no fasten tab dedicated to SG is 
provided with the HDD.  Therefore, when SG and FG are connected in the system, it is necessary to 
connect SG and FG at the power supply or to connect SG of the power supply to FG of the system. 