Fujitsu MBA3300NC Manual Do Utilizador

Página de 138
5.3.2   Each mode setting 
(1) 
Setting terminator power supply 
 
Refer to Table 5.2 for controlling the supply of power from the drive to the SCSI terminator 
power source (TERMPOW).  
 
For information on NP model, refer to Figures 5.2 and 5.3. 
Table 5.2 
Setting SCSI terminator power supply (NP model) 
Supply on/off of SCSI terminator power from 
HDD 
Pin pair 23/24 of CN2 
(TRMPOW/TRMPOW) 
Supply off 
Open 
Supply on 
Short (*1) 
*1.  Set at factory shipment. 
 
For NC model, the function of the terminator power supply setting is not supported. 
(2) 
Motor start mode 
 
Set how to control the starting of the HDD spindle motor according to Table 5.3.  This setting 
only determines the operation mode when the power supply is turned on or the microcode is 
downloaded.  In both modes, stopping or restarting the spindle motor can be controlled by 
specifying the START/STOP UNIT command. 
Table 5.3 
Motor start mode setting  
NC model (*3) 
NP model 
Start timing of the spindle motor 
Pin pair 11/12 of 
CN2 
(GND/RMSTART)
Pin 38 of CN1 
(RMT START) 
Pin 78 of CN1 
(DYLD START) 
Starting of the motor is controlled 
with the START/STOP UNIT 
command. 
Short 
Open or Short 
Open 
The motor is started immediately 
after the power supply is turned on or 
after the microcode is downloaded. 
Open Open 
Short 
(*1) 
The motor is started after the elapse 
of a delay time that is based on the 
SCSI ID.  The delay time is provided 
immediately after the power supply is 
turned on or after the microprogram 
is downloaded. 
Open Short  (*2) 
*1. Set at factory shipment. 
*2. For NP model, delay starting of spindle motor is supported by the CHANGE  DEFINITION 
command only. 
*3. To set the setting terminals on NC models to short, apply voltage ranging between-0.3 V and 0.8 
V to the setting terminals externally.  To set the setting terminals on NC models to open, apply 
voltage ranging between 2.0 V and 5.5 V to the setting terminals from an external source. 
 
Refer to Subsection 3.1.10 “START/STOP UNIT (1B)” of the SCSI Logical Interface 
Specifications for details of the START/STOP UNIT command. 
78 