Fujitsu MCM3130AP Manual Do Utilizador

Página de 202
Host Interface
4-76
C156-E227-01EN
4.6.17  SEND DIAGNOSTIC command
Table 4.105  SEND DIAGNOSTIC command
Bit
Byte
7
6
5
4
3
2
1
0
0
Operation Code (1Dh)
1
Logical Unit Number
Reserved
SelfTest
Reserved
Reserved
2
Reserved
3-4
Parameter List Length
5-11
Reserved
The SEND DIAGNOSTIC command instructs diagnostic operation from the host.
When the Self-Test bit is 1, the command executes diagnostics on the data buffer.
If an error occurs, the device responds with Check Condition.
Parameter List Length specifies the data length of diagnostic parameters to be
transferred.
The functions and specifications of diagnostic parameters are not open.
4.6.18  SEEK command
Table 4.106  SEEK command
Bit
Byte
7
6
5
4
3
2
1
0
0
Operation Code (2Bh)
1
Logical Unit Number
Reserved
2-5
Logical Block Address
6-11
Reserved
The SEEK command positions the head on the track at the specified logical block
address.
Logical Block Address specifies the logical block address at which the head is
positioned.