Fujitsu MAS3367FC Manual Do Utilizador

Página de 114
5.2  Setting 
C141-E198 
5-3 
5.2 Setting 
5.2.1 
Loop ID setting 
 
When setting the fibre channel loop ID, use SEL0 to SEL6 of interface connector CN1.  IN bit 
weighting, SEL6 corresponds to the MSB, SEL0 to the LSB, and 126 types of X'00' to X'7D' can be 
specified as loop IDs. 
5.2.2  
Mode settings 
(1)  
Motor start mode 
 
The method for start control of the IDD spindle motor can be set in accordance with Table 5.1. 
 
Table 5.1 
Motor start mode 
Setting  
Signal name 
 
Start_2/Mated Start_1/Mated 
Start 
mode 
Connector pin 
 
CN1-10 CN1-09 
 
Open 
Open 
The drive is not connected to the system.  The drive does not start the 
spindle motor. 
Open 
GND 
The drive is connected to the system.  After recognizing the 
connection, the drive starts the spindle motor upon receipt of a 
START/STOP UNIT command. 
GND 
Open 
The drive is connected to the system.  After recognizing the 
connection, the drive starts the spindle motor after a prescribed delay 
time has elapsed. 
GND 
GND 
The drive is connected to the system.  The driver starts the spindle 
motor immediately after recognizing the connection. 
 
 
 
Set the loop ID so that there are no duplicates between devices on the 
same loop.