Operations 
 
6.1  Device Response to the Reset 
This section describes how the PDIAG- and DASP- signals responds when the 
power of the IDD is turned on or the IDD receives a reset or diagnostic command. 
6.1.1  Response to power-on 
After the master device (device 0) releases its own power-on reset state, the master 
device shall check a DASP- signal for least 500 ms to confirm presence of a slave 
device (device 1).  The master device recognizes presence of the slave device 
when it confirms assertion of the DASP- signal. Then, the master device checks a 
PDIAG- signal to see if the slave device has successfully completed the power-on 
diagnostics. 
If the master device cannot confirm assertion of the DASP- signal within 500 ms, 
the master device recognizes that no slave device is connected. 
After the slave device (device 1) releases its own power-on reset state, the slave 
device shall report its presence and the result of power-on diagnostics to the 
master device as described below: 
DASP- signal:  Asserted within 450 ms. 
PDIAG- signal:  Negated within 1 ms and asserted within 30 seconds. 
The asserted PDIAG-signal is negated 30 seconds after it is asserted if the 
command is not received. 
 