Fujitsu MAP3367NC/NP Manual Do Utilizador

Página de 132
5-18
C141-E166
5.6.4
Setting parameters
The user can specify the optimal operation mode for the user system environments by setting the
following parameters with the MODE SELECT or MODE SELECT EXTENDED command:
  Error recovery parameter
  Disconnection/reconnection parameter
  Caching parameter
  Control mode parameter
With the MODE SELECT or MODE SELECT EXTENDED command, specify 1 for the "SP" bit
on CDB to save the specified parameter value on the disk.  This enables the IDD to operate by
using the parameter value set by the user when power is turned on again.  When the system has
more than one INIT, different parameter value can be set for each INIT.
When the parameters are not set or saved with the MODE SELECT or MODE SELECT
EXTENDED command, the IDD sets the default values for parameters and operates when power is
turned on or after reset.  Although the IDD operations are assured with the default values, the
operations are not always optimal for the system.  To obtain the best performance, set the
parameters in consideration of the system requirements specific to the user.
This section outlines the parameter setting procedures.  Refer to Chapter 3 of SCSI Logical
Interface Specifications for further details of the MODE SELECT and MODE SELECT
EXTENDED commands and specifying the parameters.
IMPORTANT
1.
At  factory  shipment  of  the  IDD,  the  saving  operation  for  the  MODE
SELECT  parameter  is  not  executed.    So,  if  the  user  does  not  set
parameters,  the  IDD  operates  according  to  the  default  value  of  each
parameter
2.
The model select parameter is not saved for each SCSI ID of but as the
common  parameter  for  all  IDs.    In  the  multi-INIT  System,  parameter
setting cannot be changed for each INIT.
3.
Once parameters are saved, the saved value is  effective  as  long  as  next
saving  operation  is  executed  from  the  INIT.    For  example,  even  if  the
initialization of the disk is  performed  by  the  FORMAT  UNIT  command,
the saved value of parameters described in this section is not affected.
4.
When  the  IDD,  to  which  the  saving  operation  has  been  executed  on  a
system,  is  connected  to  another  system,  the  user  must  pay  attention  to
that  the  IDD  operates  according  to  the  saved  parameter  value  if  the
saving operation is not executed at installation.