Fujitsu MHT2020AT Manual Do Utilizador

Página de 256
Device Overview
1-8
C141-E192-01EN
Figure 1.2 Current fluctuation (Typ.) at +5 V when power is turned on
(6) Power on/off sequence
The voltage detector circuits (the MHT Series) monitor +5 V.  The circuits do not
allow a write signal if either voltage is abnormal.  These prevent data from being
destroyed and eliminates the need to be concerned with the power on/off
sequence.
1.4 Environmental Specifications
Table 1.4 lists the environmental specifications.
Table 1.4 Environmental specifications
Item
Specification
Temperature
•   Operating
•   Non-operating
•   Thermal Gradient
5 °C to 55 °C (ambient)
5 °C to 60 °C (disk enclosure surface)
–40 °C to 65 °C
20 °C/h or less
Humidity
•   Operating
•   Non-operating
•   Maximum Wet Bulb
8 % to 90 % RH (Non-condensing)
5 % to 95 % RH (Non-condensing)
29 °C (Operating)
40 °C (Non-operating)
Altitude (relative to sea level)
•   Operating
•   Non-operating
–300 to 3,000 m
–300 to 12,000 m