Fujitsu MAT3300NC/NP Manual Do Utilizador

Página de 130
6-12 
C141-E201 
6.3 Operation 
Check 
6.3.1 
Initial seek operation check 
 
If an error is detected during initialization by the initial seek operation check routine at power-on, 
the LED on the front panel blinks.  The spindle motor of the disk drive then stops, and the disk 
drive is unusable. 
 
For an explanation of the operation check before the initial seek, refer to the Section 5.6. 
 
 
6.3.2 Operation 
test 
 
While the host computer is processing data, the IDD monitors disk drive operation including data 
processing, command processing, and seek operations.  If the IDD detects an error, the IDD posts 
the error to the INIT.  The INIT then posts the error to the user. 
 
The user may detect an intermittent or nonfatal error such as abnormal noise, abnormal odor, or 
very slow operation. 
 
An error posted in an operation test must be investigated.  Replace the disk drive to see whether 
the error was caused by the disk drive. 
 
Often, errors posted in an operation test may be caused by the host system.  Possible causes include 
insufficient power capacity, loose cable connection, insufficient timing or insufficient mechanical 
play, and problems related to other systems. 
 
If an operation error is detected by the error detection circuit of the disk drive, an interrupt occurs.  
The interrupt is posted to the MCU on the PCA.  The MCU stops the currently processed 
command, and causes the CHECK CONDITION status to post the error to the INIT. 
 
When receiving the CHECK CONDITION status, the INIT issues a REQUEST SENSE command 
to collect detailed information about the error.  The INIT then issues a REZERO UNIT command 
to return the read/write head to track 00.  In normal processing, the IDD itself or INIT determines 
how to handle the error (processing retry or stop). 
 
To analyze the error posted in the operation test, reconstruct the conditions in which the error 
occurred.  Then, start troubleshooting the whole host system by replacing the disk drive. 
 
 
6.3.3 Diagnostic 
test 
 
The diagnostic test is executed to find a faulty subassembly in a faulty disk drive, or to check disk 
drive performance.  This test is usually a combination of specific disk drive functions or group of 
functions.  This test may be executed using a different host computers or test equipment and away 
from the environment where the error first occurred. 
 
To analyze the error posted in the diagnostic test, reconstruct the conditions in which the error 
occurred.  Then, look for a possibly faulty subassembly or part of the disk drive. 
 
The procedures to be used in this test depend largely on the type of test equipment used, and are 
not covered by this manual.