Fujitsu MAT3300NC/NP Manual Do Utilizador

Página de 130
5-12 
C141-E201 
5.5 Connecting 
Cables 
 
Connect the IDD and system with the following cables.  See Section 4.3 for further details of the 
requirements for IDD connector positions and connecting cables.  
• 
Power cable 
• 
SCSI cable 
• 
External operator panel cable (if required for NP model) 
 
The general procedures and notes on connecting cables are described below.  Especially, pay 
attention to the inserting orientation of each cable connector. 
 
CAUTION 
 
Damage 
1.  Make sure that system power is off before connecting or disconnecting 
cables. 
 
2.  Do not connect or disconnect cables when power is on. (except NC 
model) 
 
 
a)  Connect power cable. 
 
b)  Connect the external operator panel (if required for NP model). 
 
c)  Connect the SCSI cable. 
 
d)  Fix the cables so that they do not touch the DE and PCAs, or so that the smooth flow of the 
cooling air in the system cabinet is assured. 
 
 
CAUTION 
 
Damage 
1. 
Be careful of the insertion orientations of the SCSI connectors.  With the 
system in which terminating resistor power is supplied via the SCSI 
cable, if the power is turned on, the overcurrent protection fuse of the 
terminating resistor power supplier may be blown or the cable may be 
burnt if overcurrent protection is not provided. 
 
 
When the recommended parts listed in Table 4.2 are used, inserting the 
cables in the wrong orientation can be prevented. 
 
2.  To connect SCSI devices, be careful of the connection position of the 
cable.  Check that the SCSI device with the terminating resistor is the last 
device connected to the cable.