Fujitsu MPG3153AH Manual Do Utilizador
![Fujitsu](https://files.manualsbrain.com/attachments/6c4642b33d2edbd09f94719c20a133aa0e862902/common/fit/150/50/80a45702a21fefb1823bce6851e87db450dccf7792cb572ebc8a90330a68/brand_logo.png)
C141-E112-01EN
5 - 104
5.6.4
Power-on and reset
Figure 5.20 shows power-on and reset (hardware and software reset) timing.
(1)
Only master device is present
*1: Reset means including Power-on-Reset, Hardware Reset (RESET-), and Software Reset.
Clear Reset *1
tP
tN
tM
BSY
DASP-
Power-on
RESET-
Software reset
RESET-
Software reset
(2)
Master and slave devices are present (2-drives configuration)
tP
Clear Reset
[Slave device]
[Master device]
tN
DASP-
PDIAG-
BSY
BSY
DASP-
tQ
tR
tS
Symbol
Timing parameter
Min.
Max.
Unit
tM
Pulse width of RESET-
25
—
µ
s
tN
Time from RESET- negation to BSY set
—
400
ns
tP
Time from RESET- negation to DASP- or DIAG- negation
—
1
ms
tQ
Self-diagnostics execution time
—
30
s
tR
Time from RESET- negation to DASP- assertion (slave device)
—
400
ms
tS
Duration of DASP- assertion
—
31
s
Figure 5.20 Power-on Reset Timing