Fujitsu MPB3043AT Manual Do Utilizador

Página de 180
C141-E045-02EN
5 - 16
5.3.2
Command descriptions
The contents of the I/O registers to be necessary for issuing a command and the example
indication of the I/O registers at command completion are shown as following in this
subsection.
Example:  READ SECTOR(S) WITH RETRY
At command issuance (I/O registers setting contents)
Bit
7
6
5
4
3
2
1
0
1F7
H
(CM)
0
0
1
0
0
0
0
0
1F6
H
(DH)
×
L
×
DV
Head No. / LBA [MSB]
1F5
H
(CH)
Start cylinder address [MSB]
/ LBA
1F4
H
(CL)
Start cylinder address [LSB] / LBA
1F3
H
(SN)
Start sector No.
/ LBA [LSB]
1F2
H
(SC)
Transfer sector count
1F1
H
(FR)
xx
At command completion (I/O registers contents to be read)
Bit
7
6
5
4
3
2
1
0
1F7
H
(ST)
Error information
1F6
H
(DH)
×
L
×
DV
Head No. / LBA [MSB]
1F5
H
(CH)
Start cylinder address [MSB]
/ LBA
1F4
H
(CL)
Start cylinder address [LSB] / LBA
1F3
H
(SN)
Start sector No.
/ LBA [LSB]
1F2
H
(SC)
X‘00’
1F1
H
(ER)
Error information
CM:  Command register
FR:  Features register
DH:  Device/Head register
ST:  Status register
CH:  Cylinder High register
ER:  Error register
CL:  Cylinder Low register
L:     LBA (logical block address) setting bit
SN:  Sector Number register
DV:  Device address. bit
SC:  Sector Count register
x, xx:  Do not care (no necessary to set)