Fujitsu DX8100 S2 Manual Do Utilizador

Página de 1066
Chapter 9  Connectivity Management
  9.2  Functions in the Action Area for Connectivity
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED
P2X0-1090-10ENZ0
567
3
Click the [OK] button.
→ Modification of the iSCSI port parameters starts.
4
Click the [Done] button to return to the [iSCSI Port Group] screen.
End of procedure
9.2.3.9
Modify SAS Port Parameters
This function sets the connection information for the SAS port that is used to connect the ETERNUS DX Disk
storage system and the host.
The procedure to set SAS port parameters is as follows:
Procedure
1
Select the SAS port to set the parameters for (multiple selections can be made) and click 
[Configure SAS Port] in [Action].
2
Set the parameters for all of the selected ports and click the [Set] button.
Port
Select the target port.
The selectable port location options are displayed as options:
-
CM#x CA#y Port#z (x: CM number, y: CA number, z: Port number)
When changing port parameters during operation, stop access from the server that is allocated to the target 
port. Host access does not need to be stopped to change the port parameters of newly added CA ports.
For more details on SAS parameter settings, refer to "User’s Guide -Server Connection-" for each OS type.
When multiple ports are selected, select the target port and set the parameters for each port.