Fujitsu MHT2060BH Manual Do Utilizador

Página de 264
Device Overview 
 
 
1-12 C141-E203-01EN 
Emergency Unload other than Normal Unload is performed when the power is 
shut down while the heads are still loaded on the disk. 
The product supports the Emergency Unload a minimum of 20,000 times. 
When the power is shut down, the controlled Normal Unload cannot be executed. 
Therefore, the number of Emergency other than Normal Unload is specified. 
Remark: 
We recommend cutting the power supply of the HDD for this device after the 
Head Unload operation completes. The recommended power supply cutting 
sequence for this device is as follows: 
1) Disk 
Flush 
Flush Cache command execution. 
2) Head 
Unload 
Standby Immediate command execution. 
3) Wait 
Status 
Checking whether bit 7 of the status register was set to '0'. 
(wait to complete STANDBY IMMEDIATE command) 
4)  HDD power supply cutting 
 
1.11   Advanced Power Management 
The disk drive shifts to the three kinds of APM modes automatically under the 
Idle condition. 
The APM mode can be chosen with a Sector Count register of the SET 
FEATURES(EF) command. 
In APM Mode-1, which is the APM default mode, the operation status shifts till it 
finally reaches "Low Power Idle." 
The disk drive complies with the three kinds of APM modes that a command 
from the host is required. 
FR = 05h  :   Enable APM 
SC = C0h - FEh  : 
Mode-0 Active Idle 
 Low Power Idle 
SC = 80h - BFh  : 
Mode-1 Active Idle 
 Low Power Idle (Default) 
SC = 01h - 7Fh  : 
Mode-2 Active Idle 
 Low Power Idle 
 Standby 
FR = 85h  :   Disable APM (Set Mode-0)