Fujitsu MAF3364LP Manual Do Utilizador

Página de 133
C141-E064-03EN
5 - 7
Table 5.1
SCSI ID setting (CN2)
SCSI ID
CN2
7-8
5-6
3-4
1-2
0
Open
Open
Open
Open
1
Open
Open
Open
Short
2
Open
Open
Short
Open
3
Open
Open
Short
Short
4
Open
Short
Open
Open
5
Open
Short
Open
Short
6
Open
Short
Short
Open
7
Open
Short
Short
Short
8
Short
Open
Open
Open
9
Short
Open
Open
Short
10
Short
Open
Short
Open
11
Short
Open
Short
Short
12
Short
Short
Open
Open
13
Short
Short
Open
Short
14
Short
Short
Short
Open
15 (*1)
Short
Short
Short
Short
*1  Set at factory shipment
IMPORTANT
1.
Set the SCSI ID so that there are no duplicates between SCSI devices
on the same SCSI bus.
2.
The priority of SCSI bus use in ARBITRATION phase is determined by
SCSI ID as follows:
7 > 6 > 5 > 4 > 3 > 2 > 1 > 0 > 15 > 14 > 13 > 12 > 11 > 10 > 9 > 8
5.3.2 
Each mode setting
(1)
Setting terminal power supply
Refer to Table 5.2 for controlling the supply of power from the drive to the SCSI terminal resistance
power source (TERMPOW).  However, this setting may not be used with SCA2 type 16 bit-SCSI
(LC/MC).  For information on LP/MP, refer to Figures 5.2 and 5.3.
Table 5.2
Setting SCSI terminal power supply (LP/MP)
Supply on/off of SCSI terminating resistor power from IDD
CN2 23-24
Supply off
Open
Supply on
Short (*1)
*1  Setting at factory shipment