Fujitsu MAP3147FC Manual Do Utilizador

Página de 114
Installation
5-12
C141-E163
5.5.4Setting parameters
The user can specify the optimal operation mode for the user system environments by setting the
following parameters with the MODE SELECT or MODE SELECT EXTENDED command:
  Error recovery parameter
  Disconnection/reconnection parameter
  Caching parameter
  Control mode parameter
With the MODE SELECT or MODE SELECT EXTENDED command, specify 1 for the "SP" bit on
CDB to save the specified parameter value on the disk.  This enables the IDD to operate by using the
parameter value set by the user when power is turned on again.  When the system has more than one
INIT, different parameter value can be set for each INIT.
When the parameters are not set or saved with the MODE SELECT or MODE SELECT
EXTENDED command, the IDD sets the default values for parameters and operates when power is
turned on or after reset.  Although the IDD operations are assured with the default values, the
operations are not always optimal for the system.  To obtain the best performance, set the parameters
in consideration of the system requirements specific to the user.
This section outlines the parameter setting procedures.  Refer to Chapter 3 of Fibre Channel Interface
Specifications for further details of the MODE SELECT and MODE SELECT EXTENDED
commands and specifying the parameters.
1.
At  factory  shipment  of  the  IDD,  the  saving  operation  for  the  MODE
SELECT parameter is not executed.  So, if the user does not set parameters,
the IDD operates according to the default value of each parameter
2.
The  model  select  parameter  is  not  saved  for  each  Loop  ID  of  but  as  the
common parameter for all IDs.  In the multi-INIT System, parameter setting
cannot be changed for each INIT.
3.
Once  parameters  are  saved,  the  saved  value  is  effective  as  long  as  next
saving  operation  is  executed  from  the  INIT.    For  example,  even  if  the
initialization of the disk is performed by the FORMAT UNIT command, the
saved value of parameters described in this section is not affected.
4.
When  the  IDD,  to  which  the  saving  operation  has  been  executed  on  a
system, is connected to another system, the user must pay attention to that
the  IDD  operates  according  to  the  saved  parameter  value  if  the  saving
operation is not executed at installation.