Fujitsu MAP3147FC Manual Do Utilizador

Página de 114
Error Analysis
7-4
C141-E163
7.2.2
Sense data (3-0C-03), (4-40-xx), (4-44-xx), and (4-C4-xx)
Sense data (3-0C-03), (4-40-xx), (4-44-xx), and (4-C4-xx) indicate one of the following:
 
A target sector could not be detected using the sector counter.
 
A seek process overran the specified time.
 
A write to a disk terminated abnormally.
 
An error occurred in power-on self-diagnosis.
 
A hardware error occurred inside IDD.
 
A drive error occurred.
The symptoms above are generally caused by an error in a PCA or DE.
For details of the sense data above, refer to the Fibre Channel Interface Specifications.
7.2.3
Sense data (1-1x-xx), (3-1x-xx) and (E-1D-00):  Disk read error
If sense data (1-1x-xx), (3-1x-xx) or (E-1D-00) occurs frequently in a specific block of a disk, there
is disk damage that was not recorded in the media defect list.  In this case, assign an alternate block
to the error-detected block using a REASSIGN BLOCKS command.  For an explanation of the
REASSIGN BLOCKS command, refer to the Fibre Channel Interface Specifications.
If this error occurs in different blocks, a PCA or DE is faulty.
For details of the above sense data, refer to the Fibre Channel Interface Specifications.
7.2.4
Sense data (5-2x-xx), (5-3D-00), (B-47-xx), (B-49-00), (B-4D-xx) and (B-4E-00): fibre channel
interface error
Sense data (5-2x-xx), (5-3D-00), (B-47-xx), (B-49-00), (B-4D-xx) and (B-4E-00) indicates one of
the following symptoms:
 
An  invalid  or  unsupported  command  was  issued,  or  invalid  or  unsupported  parameters  were
specified.
 
A SCSI error occurred.
 
A CRC error occurred in the fibre channel loop.
If this error occurs, a PCA or the fibre channel interface is faulty.
For details of the above sense data, refer to the Fibre Channel Interface Specifications.