Fujitsu F2MC-8FX Manual Do Utilizador

Página de 272
210
CHAPTER 6  DETAILED RULES FOR EXECUTION INSTRUCTIONS
6.82 XCHW (eXCHange Word Data Accumulator and Stack 
Pointer)
Exchange the word data of A for that of SP.
XCHW (eXCHange Word Data Accumulator and Stack Pointer)
Operation
(A) 
↔ (SP) (conversion of word data)
Assembler format
XCHW A, SP
Condition code (CCR)
+: Changed by executing instruction
-: Not changed
N: Not changed
Z: Not changed
V: Not changed
C: Not changed
Number of execution cycles: 2
Byte count: 1
OP code: F5
N
Z
V
C
-
-
-
-