CHAPTER 6  DETAILED RULES FOR EXECUTION INSTRUCTIONS
6.86 XORW (eXclusive OR Word Data of Accumulator and 
Temporary Accumulator to Accmulator)
Carry out the logical exclusive-OR on the word data of A and T for every bit and return 
the results to A.
XORW (eXclusive OR Word Data of Accumulator and Temporary Accumulator to 
Accmulator)
Operation
(A) 
← (A) ∀ (T) (word logical exclusive-OR)
Assembler format
XORW A
Condition code (CCR)
+: Changed by executing instruction
-: Not changed
R: Set to 0 by executing instruction
N: Set to 1 if the MSB of A is 1 as the result of operation and set to 0 in other cases.
Z: Set to 1 if the result of operation is 0000
H
 and set to 0 in other cases.
V: Always set to 0
C: Not changed
Number of execution cycle: 1
Byte count: 1
OP code: 53
N
Z
V
C
+
+
R
-