CHAPTER 6 DETAILED RULES FOR EXECUTION INSTRUCTIONS
6.16 BZ (Branch relative if Z = 1)/BEQ (Branch if Equal)
Execute the next instruction if the Z-flag is 0 and the branch if it is 1 . Branch address
corresponds to the value of addition between the PC value (word value) of the next
instruction and the value with rel code-extended (word value).
corresponds to the value of addition between the PC value (word value) of the next
instruction and the value with rel code-extended (word value).
■
BZ (Branch relative if Z = 1)/BEQ (Branch if Equal)
Operation
(Z) = 0: (PC)
← (PC) + 2 (Word addition)
(Z) = 1: (PC)
← (PC) + 2 + rel (Word addition)
Assembler format
BZ rel/BEQ rel
Condition code (CCR)
+: Changed by executing instruction
-: Not changed
N: Not changed
Z: Not changed
V: Not changed
C: Not changed
Number of execution cycles: 4 (at divergence)/ 2 (at non-divergence)
Byte count: 2
OP code: FD
N
Z
V
C
-
-
-
-