Mocomtech CDM-570L Manual Do Utilizador

Página de 452
CDM-570/570L Satellite Modem with Optional IP Module 
Revision 4 
Serial Remote Control 
MN/CDM570L.IOM 
13–2 
Each target has a unique address, and each time the controller transmits, in a framed 
‘packet’ of data, the address of the intended recipient target is included. All of the targets 
receive the packet, but only one (the intended) will reply. The target enables its output 
line driver, and transmits its return data packet back to the controller, in the other 
direction, on the physically separate pair. 
 
RS-485 (full duplex) summary:  
•  Two differential pairs  - one pair for controller to target, one pair for target to 
controller. 
•  Controller-to-target pair has one line driver (controller), and all targets have line-
receivers. 
•  Target-to-controller pair has one line receiver (controller), and all targets have 
tri-state drivers.  
13.3 RS-232 
 
This a much simpler configuration in which the controller device is connected directly to 
the target via a two-wire-plus-ground connection. Controller-to-target data is carried, via 
RS-232 electrical levels, on one conductor, and target-to-controller data is carried in the 
other direction on the other conductor. 
 
13.4 
Basic Protocol  
Whether in RS-232 or RS-485 mode, all data is transmitted as asynchronous serial 
characters, suitable for transmission and reception by a UART. In this case, the only 
supported asynchronous character format is 8N1 (8 data bits, no parity, 1 stop bit). The 
baud rate may vary between 2400 and 57600 baud.  
 
All data is transmitted in framed packets. The controller is assumed to be a PC or ASCII 
dumb terminal, which is in charge of the process of monitor and control. The controller is 
the only device which is permitted to initiate, at will, the transmission of data. Targets are 
only permitted to transmit when they have been specifically instructed to do so by the 
controller.   
  
All bytes within a packet are printable ASCII characters, less than ASCII code 127. In 
this context, the Carriage Return and Line Feed characters are considered printable. 
 
All messages from controller to target require a response (with one exception). This will 
be either to return data which has been requested by the controller, or to acknowledge 
reception of an instruction to change the configuration of the target. The exception to this 
is when the controller broadcasts a message (such as Set time/date) using Address 0, 
when the target is set to RS-485 mode.