Telect MIX 56 Manual Do Utilizador

Página de 124
4  Software Operation
MIX 56 User Manual
4-42
Telect, Inc. 122188-10 A0
Step
Action
1.
From the Directory screen, press 17 to select Alarm Log, then En-
ter.
The Alarm Log screen appears.  
2.
Tab to “Card Select” and press the space bar to toggle between 
“Active” and “Standby”. Press Enter.
3.
To view the next 11 entries, tab to the [Next] button and press Enter.
4.
To view the previous 11 entries, tab to the [Previous] button and 
press Enter.
5.
To clear the entire log, tab to the [Clear] button and press Enter. A 
prompt appears asking you to confirm the clear. Type y and press 
Enter. The Alarm Log clears.
Setting Alarm Thresholds
In the Alarm Thresholds screen, you can specify some of the conditions 
that trigger and clear the system alarms. Each threshold is counted in one 
second increments, and for most alarms, you can set one threshold to trig-
ger the alarm and another to clear it (ES and SES alarms do not need Alarm 
Off thresholds because they clear automatically when the time span on 
which they are based passes).
MIX 56 by Telect                   system 2                   Directory (Ctrl+D)
                                                                        Help (?)
                               Alarm Log - Active                              
                               ------------------
Card Select: Active
#  Date      Time     Alarm Details
-- --------- -------- ----- ---------------------------------------------------
 1 22/Oct/03 07:37:35 Mnr   System,multiple low speed failures,on
 2 22/Oct/03 07:37:35 Crt   LS-02(Low Speed 02),Rx AIS,off
 3 22/Oct/03 07:37:35 Mnr   LS-02(Low Speed 02),LOS,on
 4 22/Oct/03 07:37:18 Crt   24 hr. SES HS threshold crossed,off
 5 22/Oct/03 07:37:18 Mnr   24 hr. ES HS threshold crossed,off
 6 22/Oct/03 07:37:18 Crt   15 min. SES HS threshold crossed,off
 7 22/Oct/03 07:37:18 Crt   15 min. ES HS threshold crossed,off
 8 22/Oct/03 07:36:52 Crt   System,standby card detected critical alarm,off
 9 22/Oct/03 07:36:51 Crt   HS-01(High Speed),LOS,off
10 22/Oct/03 07:30:00 Mnr   24 hr. ES HS threshold crossed,on
11 22/Oct/03 07:29:59 Mnr   24 hr. SES LS threshold crossed,on
                                                  [Next]  [Previous]  [Clear]