Chapter 4  Troubleshooting  
IP-900 Series 
109 
Classification Symptom 
Check Corrective 
action 
Is the monitor power on? 
Check the monitor power and operation. 
Is IP-900 series power on? 
Confirm that the PWR-LED is on. 
No video is 
output 
(black screen) 
Is IP-900 series correctly 
connected to the monitor? 
Check the connection between the IP-900 series 
and monitor. 
Has decoding started? 
See Section 3.5.3, "Operation & Status 
(Decoder)," and confirm that "Normal 
(Receiving)" is displayed for "Decoding." 
Is the setup normal? 
Check the streaming address and port number 
settings. 
Blue/gray 
screen is 
output. 
Is "Operating" displayed 
for "Encoding" on the 
streaming source device? 
Confirm that the streaming source device is 
distributing streams.  In the case of the IP-900 
series encoder, see Section 3.3.4, "Operation & 
Status (Encoder)" and confirm that "Operating" is 
displayed for "Encoding." 
In the case of Unicast, confirm that the number of 
possible streams of encoder is observed. 
Only color 
bars are 
displayed. 
Is the video input of the 
source device normal? 
In the case of IP-900 seriese encoder, if video 
input is not received, the encoder outputs color 
bars or gray view according to the setting of 
"Display when no video signal input" on the AV 
input setup page.  Check video input. 
 
Is the copy protected 
content like DVD input to 
HDMI interface? 
The HDMI signal protected by HDCP 
(High-bandwidth Digital Copy Protection system) 
cannot be input to IP-900 series from the view 
point of the copy right protection. 
Check video input. 
Is a receiving error present?
Check the number of data packets received 
(decoder information) according to Section 
3.2.11, "Performance Statistics." 
Display the Performance Summary frame several 
times.  If the number of data packets lost is 
counted up, the network load may be high or there 
may be a problem with the setting.  Consult your 
network administrator. 
Video 
Receiving 
video 
sometime 
stops or video 
image is 
unstable. 
Is the MTU size too small? 
Use the size recommended for the network used. 
Is IP-900 series power on? 
Confirm that the PWR LED is on. 
Is IP-900 series correctly 
connected to the speaker? 
Check the connection between IP-900 series and 
speaker. 
Is the volume of the speaker 
used too low? 
Check the volume of the speaker. 
Is an alarm generated on the 
streaming source device? 
If an alarm is generated, see the operating manual 
of the streaming source device. 
No sound is 
generated. 
Is the streaming source device 
correctly connected to the 
audio source? 
Check the connection of the audio cable. 
Disconnect the audio output 
cable from IP-900 series  Does 
it eliminate the noise? 
If noise does not disappear even after the cable is 
disconnected, check the audio cable and audio 
output equipment. 
Audio 
Noise is 
generated. 
Is a receiving error present?  
Check the number of data packets received 
(decoder information) according to Section 3.2.11, 
"Performance Statistics." 
Display the Performance Statistics frame several 
times.  If the number of data packets lost is counted 
up, the network load may be high or there may be a 
problem with the setting.  Consult your network 
administrator. 
Data Data 
communication 
is disabled. 
Is the port setting normal? 
Is the port setting consistent 
with the destination device? 
Check the setting according to Section 3.2.6, "Data 
Port."