Lexmark E310 Manual Do Utilizador

Página de 154
Diagnostic Information
2-21
4044-XXX
Hot Fuser Service Check
Main Motor Service Check
FRU
Action
Model E310
Fuser Thermistor
Disconnect the thermistor cable from 
the LVPS. Measure the resistance 
across CN1-1 and CN1-2 of the 
thermistor cable. Replace the 
thermistor if the resistance is lower 
than 1k ohm or shorted.
Model E312
Fuser Thermistor
Disconnect the thermistor cable from 
the engine board. Measure the 
resistance across CN10-1 and 
CN10-3 of the thermistor cable. 
Replace the thermistor if the 
resistance is lower than 1k ohm or 
shorted.
Models E310 & E312
Fuser Lamp
Make sure the correct voltage fuser 
lamp is installed. Replace if 
necessary.
FRU
Action
Model E310
Interconnect Board
Main Motor
Main Motor Cable
Check the interconnect board for the 
following voltages:
CN405-3 +24 V dc
CN405-4 +24 V dc
If these voltages are not correct, 
replace the interconnect board. If 
these voltages are correct, check the 
main motor cable for continuity. If 
continuity exists on each wire, 
replace the main motor. If continuity 
does not exist on one or more of the 
wires, replace the cable.