Lexmark 4069-XXX Manual Do Utilizador

Página de 376
Diagnostic Aids
3-17
4069-XXX
If the high capacity output stacker is selected then the following is 
displayed:
HC BIN 1
TP=OP, P=OP, F=OP, NF=OP
IP = high capacity output stacker top position sensor
P = high capacity output stacker passthru sensor
F = high capacity output stacker full sensor
NF = high capacity output stacker near full sensor
If the 5-bin mailbox is selected the following is displayed:
<output bin> (output bin displayed on line 1 = output bin 1, 
output bin2, output bin3, output bin4 or output bin 5 for the bin 
selector)
P1 = 5-bin mailbox first passthru sensor
P2 = 5-bin mailbox second passthru sensor
L = EM, indicates 5-bin x empty
L = NL, bin contains media but the bin is not near full on full
L = NF, indicates bin is near full
L = FL, indicates bin is full
Base Sensor Test
This test is used to determine if the sensors located inside the 
printer are working correctly.
The following sensors can be checked:
Toner Optical Sensor
Input Sensor
Output Sensor (Fuser Exit)
Narrow Media Sensor
Front Door Sensor (Upper Front Cover)
To run the Base Sensor Test:
1. Select the Base Sensor Test.
– The operator panel displays OP for open and CL for closed.
2. Manually toggle the sensors by hand to verify that each sensor 
switches from open to closed.