The fuser lamp FRU is color coded. The left and right fuser lamp 
bracket access holes let you view the end of the lamp. Use the 
following table to identify and install the correct lamp.
Fuser Lower Exit Guide Assembly 
1. Remove the fuser assembly.
2. Remove the fuser cover assembly.
3. Remove the fuser detack housing assembly.
4. Disconnect the sensors from the fuser board.
5. Gently apply outward pressure on the left and right fuser side 
frames to release the lower exit guide assembly.
Description
Color Code
Fuser Lamp 115V 550W
Green
Fuser Lamp 115V 875W
Gold
Fuser Lamp 220V 550W
Brown
Fuser Lamp 220V 875W
Silver