Diagnostic Information
2-35
4069-XXX
Duplex Option Service Check
The printer does not recognize the Duplex Option is attached. The 
printer does not recognize tray options below the duplex option 
are installed.
FRU
Action
1
Fuse F1 on Duplex Option 
System Board
If fuse F1 is blown, replace the fuse. 
If fuse F1 continues to blow, check 
the stepper motor for a short 
between the motor case and pins 
J3-1 through J3-4. If no problem is 
found, check the D.C. servo motor 
pins J1-1 and J1-2 to the motor 
housing for a short. If a short is 
found, replace the motor assembly. If 
no short is found, replace the system 
board.
2
Autoconnect Cables/
Connectors
Check the autoconnect cables for 
damage to the cables or the pins in 
the connectors. If damaged, replace 
the cable(s). If no damage is found, 
check to make sure the cables are 
connected to J9, J10, J11 and J12 
on the duplex system board. If no 
problem is found, replace the duplex 
system board.