Seiko Group BP-9000 Manual Do Utilizador

Página de 146
(12)  Start and stop characters:   DC4 DC4 N
Format:
ASCII
DC4
DC4
N
n1
n2
Hex
14
14
4E
n1
n2
Decimal
20
20
78
n1
n2
Function:  Specifies the Codabar start or stop character.  n1 selects the
start or stop character.  n2 specifies a code of the start or stop 
as shown below.
n1 =  0: Start character
1: Stop character
n2 = 
a, b, c, d, t, n, ✽, or e.  
When power is turned on, “a” is selected as the start or stop character.
(13)  Bar code rotational angle:  DC4 DC4 R
Format:
ASCII
DC4
DC4
R
n
Hex
14
14
52
n
Decimal
20
20
82
n
Function:  Specifies the rotational angle of the bar code in units of 90 degrees.
n   =   0:      0° (Default value)
1:    90°
2:  180°
3:  270°
(14)  Disabling HRI of the start and stop characters:  DC4 DC4 S
Format:
ASCII
DC4
DC4
S
n
Hex
14
14
53
n
Decimal
20
20
83
n
Function:  Specifies whether or not to print the start or stop character in the 
for Codabar, Code 11, Code 39 or Code 93.
n  =  0: The start or stop character is printed in the HRI.  
(Default value)
1:  The start or stop character is not printed in the HRI.
(15)  Value input mode:  DC4 DC4 V
Format:
ASCII
DC4
DC4
V
n
Hex
14
14
56
n
Decimal
20
20
86
n
Function:     Specifies whether bar code sequence data is regarded as the normal
character code or a character value when Code 128 is selected.
n = 0:  Data is regarded as normal character code.  (Default value)   
1:  Data is regarded as a character value.
If data is regarded as the normal character code, the printer
automatically move the subset or inserts a shift code according to 
the data.
9.  Bar code and enlarged character