33
)(('.H\DQG3$86(.H\6HOI7HVW
Pressing these two keys at the same time, while turning the power ON, 
temporarily resets the printer configuration to the factory default values.  
These values remain active until power is turned OFF.  Whenever the 
printer is reset to factory defaults, a media calibration procedure must 
be performed immediately.  
See page 43 for details.
02'(.H\6HOI7HVW
This test places the printer in the communications diagnostics mode.  In 
this mode, the printer prints the ASCII characters and their corresponding 
hexadecimal values for any data received from the host computer.  A 
typical printout from this test is shown in Figure 15.
Note:   This label is inverted when printed.
Figure 15
3$86(.H\DQG&$1&(/.H\6HOI7HVW
This test prints a maximum of 500 head test labels.  Each label backfeeds 
prior to printing and feeds forward to the rest position after printing.  A 
serialized number prints on each label.  Press the PAUSE key or turn the 
printer power OFF to stop printing.  The labels look like the one in Figure 
13 exc
ept that a serialized number prints on each label.