This section contains troubleshooting charts used to localize and repair the 
printer when faults occur.  The procedures called out in the ACTION 
column may be performed by the operator or by a service technician when 
indicated.
SYMPTOM
DIAGNOSIS
ACTION
All indicator lights never light.
No AC power applied to the 
printer.
Ensure that the AC power 
cable is connected to a 
working voltage source.
Faulty AC power fuse.
Refer to page 9 for fuse 
replacement procedures.
No voltage available from the 
internal power supply.
Call a service technician.
Printer locks up when running 
Power-On Self Test.
An improper configuration was 
set.
Reload factory defaults,  then 
set correct parameters (see 
the instructions that begin on 
page 28).
POWER light ON, other lights 
all OFF or all ON and the 
printer locks up.
ROM CRC test has failed.
Call a service technician.
CALIBRATE light is OFF but 
all other lights are on.
Dynamic RAM failed.
Call a service technician.
CALIBRATE light and 
POSITION light OFF but all 
other lights ON.
FONT ROM error.
Call a service technician.
PRINTHEAD light is ON, 
printing continues.
Printhead under-temperature 
condition.
Wait until printhead warms up.  
If condition persists and print 
quality is affected, move 
printer to warmer environment.  
If print quality is acceptable, 
no action is required.