Chapter 12: Firmware Upgrade 
 
168
 
 
6.  (Optional) If this is your first time to download the program or 
firmware from the Raritan website, fill in the Firmware Request form, 
and click Submit
7.  When you see the http hyperlink on the right pane, click it. 
8. Click 
Save to save the file on your computer. 
9.  Specify the location where you want to save the file, and click Save
Wait until the download completes. 
10.  Extract the file if it is a ZIP file. The extracted files include the newest 
Paragon Update utility, .hex files, and so on. The .hex file is a 
firmware file. 
11.  (Optional) For some versions, such as version 4.2, the downloaded 
firmware file does not include associated release notes. When this 
occurs, locate the release notes and download it from the same 
webpage where the firmware files are located. 
12.  Read the release notes for any necessary information. 
 
STEP (B): Establish a Connection between the Device and the PC 
The device intended to upgrade must be connected to the PC that runs 
the Paragon Update utility. There are two types of connections 
depending on your device. 
 
Network connection: If your device comes with a LAN port, such as 
Paragon II Main Unit, upgrade it by connecting it to the network and 
assigning an IP address to it. However, for Paragon II Stacking Unit, 
it must be upgraded by connecting to the Main Unit which is 
connected to the network. 
 
RS-232 connection: For those devices without the network port, 
such as user stations, this is the only method to upgrade them. 
Connect the device to one of the serial ports of the PC that runs the 
Paragon Update utility via the RS-232 cable. 
Note: One DB9 male-to-female serial (RS-232) cable is shipped with 
the user station. It is a direct cable that can be used to upgrade the 
firmware with TXD, RXD and GND signals.