Raritan Computer DKX2-v2.6.0-0R-E Manual Do Utilizador

Página de 408
 
Chapter 8: Device Management 
 
 
149
 
 
6.  In the Tier Secret field, enter the same secret word you entered for 
the base device on the Device Settings page. Click OK.   
 
Tiering - Target Types, Supported CIMS and Tiering Configurations 
Blade Chassis 
Blade chassis that attached directly to the base are accessible.   
Power Control 
You can power on and off targets that are a part of the tiered 
configuration. These targets are accessed from the Port Access page. 
KX II PDU outlets can be accessed and controlled via a tiered 
configuration with either the KX II or KX2-808, KX2-832 and KX2-864 
models. If targets and outlets are associated, power control is available 
from the Port Access page.   
Targets and PDU outlet associations are limited to those attached to the 
same KX II. 
PDUs attached to the base or tiered KX IIs are displayed on the Power 
page drop-down along with the statistics for the selected powerstrip.   
Outlet level control is available as well.   
Specifically, you can power off outlets that are currently on but you 
cannot power cycle outlets that are currently off. 
KX II to KX II or KX2-8xx Local Port Configuration - Compatible 
CIMS
 
The following CIMS are compatible when you are configuring a base KX 
II to access and control either additional KX II, or KX2-808, KX2-832 and 
KX2-864 models, as well as KX II PDUs and blade chassis.   
If you are using a KX II to KX II configuration, the D2CIM-DVUSB must 
be used. If you are using a KX II to KX2-8xx configuration, only the 
extended local port can be used. 
If you are using a configuration that consists of a KX II and KX2-808, 
KX2-832 or KX2-864, each device must be using the same firmware 
version. Where blade chassis are a part of a configuration, each blade 
chassis counts as one target port.