Configure RMON Alarms 
The Alarms Table stores configuration records that define statistics, their polling 
periods and threshold parameters. 
Figure 59: RMON Alarm Configuration Table screens 
My Switch               RMON Alarms  
                
     Admin Access     
 
Index Variable                               Rising Thr   Falling Thr 
1     ifInOctets.5                           10000        100000 
2     ifOutOctets.5                          10000        100000 
More right ... 
 
<CTRL>
Z-Help S-Shell I-Insert L-Delete
Index 
The index of the RMON Alarms entry.  
Variable 
The MIB object identifier of the particular variable to be sampled.  Only variables 
that resolve to an ASN.1 primitive type of INTEGER (INTEGER, Integer32, 
Counter32, Counter64, Gauge, or TimeTicks) may be sampled.  The “rmon” shell 
command will list the names of the objects that are eligible for monitoring with 
RMON Alarms.  A detailed description of the objects is also included in Appendix 
D – RMON Acceptable MIB Parameters.  
If the statistic is port based, a decimal point and the port number must be 
appended to the identifier. 
Rising Threshold 
A rising threshold for the sampled statistic, the value the statistic must rise above 
before a rising alarm will be generated. 
Falling Threshold 
A falling threshold for the sampled statistic, the value the statistic must decrease to 
before a falling alarm will be generated. 
Value 
The value of the statistic during the last sampling period.  This is the value that is 
compared with the rising and falling thresholds. 
Type 
The method of sampling the selected variable and calculating the value to be 
compared against the thresholds. 
Interval 
The time interval in seconds over which the data is sampled and compared with 
the rising and falling thresholds. 
 