RuggedCom RS1600 Manual Do Utilizador

Página de 130
Chapter 8 – Diagnostics 
Each alarm has an associated description string.  The string will include a port 
number if it is relevant.  The description may also provide an indication of the 
recent rate at which this alarm is occurring (if the alarm has occurred previously).  
Alarms And The Critical Failure Relay 
All active alarms will immediately de-energize the critical fail relay (thus signifying 
a problem).  The relay will be re-energized when the last outstanding active alarm 
is cleared.  
Viewing And Clearing Alarms 
Viewing Alarms 
The Alarms Menu is available from the Diagnostics menu View Alarms command.  
Alarms are displayed in the order in which they occurred, even if the real time 
clock was incorrect at the time of the alarm. 
Figure 48: Alarms Menu 
My Switch                Alarms                                         6 ALARMS! 
 
Level Time         Description 
WARN  Jan  5 17:55 Port 8 down is occurring (2 times in 192 sec) 
WARN  Jan  5 18:30 Port 13 down has occurred (9 times in 19 hr) 
WARN  Jan  5 19:10 Port 5 is down 
WARN  Jan  6 13:44 Port 7 down has occurred (2 times in 23 hr) 
WARN  Jan  6 17:40 Port 12 was down 
WARN  Jan  6 23:02 Port 6 is down 
 
 
<CTRL>  Z-Help S-Shell D-PgDn U-PgUp 
Clearing Alarms 
The Diagnostics menu Clear Alarms command will clear all alarms.
RuggedCom 
73