Cascade Configuration
Cascade Configuration
Cascade Configuration
Cascade Configuration
 
 
Connection 
 
Before connecting a device (a computer or a Slave) to the Master 
under power, you must turn off the device.    The Master must have 
equal or more 'PC x' ports than that of the Slave, i.e., if KNV108 is 
the master, KNV108 and KNV104 can be Slaves, but KNV116D can 
not. 
 
The ports labeled "PC 1"~”PC 8” can be connected to either a 
computer or a Slave's  CONSOLE port, as shown in figure 10.    The 
ports “PC A"~”PC H” can only be connected to a computer.  A 
power adapter with DC 9V/500mA output rating must be connected 
to the Master
 
 
 
Figure 10: Slave console connection
 
 
The maximum number of computers controlled by a master/slave 
configuration with all KNV104s is 16 with 4 Slaves and each Slave 
connects to 4 computers, see figure 11.  For an all KNV108s 
configuration, the number is 64 with 8 Slaves and each Slave 
connects to 8 computers, see figure 12. For an all KNV116D 
configuration, the number is 136, see figure 13.  The Master 
KNV116D connects to 8 Slaves and 8 computers, and each Slave 
connects to 16 computers. 
 
 