CSS components
Non-hot-plug components
8.2
Non-hot-plug components
V
CAUTION!
The actions described in this section may only be performed by 
personnel with the appropriate technical training. (The device can be 
seriously damaged if it is opened without authorization or if repairs 
are attempted by untrained personnel.)
The circuit boards and soldered parts of internal options are exposed 
and can be damaged by static electricity. Before handling them, first 
touch a metal part on the server to discharge static electricity from 
your body. 
Do not touch the circuitry on boards and soldered parts. Hold the 
metallic areas or the edge of the circuit boards. 
Touch only the specified part of the printed circuit board. Failure to do 
so may cause injury. It may also cause failures. 
Please observe the safety information in 
.
If a defective non-hot-plug component is detected (for more information, 
see chapter 
 and the "ServerView 
Suite Local Service Concept - LSC" manual on the ServerView Suite 
DVD 2), proceed as follows:
Ê
Exit all applications and shut down the server properly (see section 
).
Ê
Pull all power connectors out of the power outlets.
Ê
Remove the server from the rack (see section 
) and place the server on a 