Hardware installation
I
Under certain circumstances, you will not be able to use some of the 
parts from the rack installation kit supplied - you will need to use 
original 3rd party rack parts instead.
Racks with installation depth of 735 mm
The lengths of the telescopic rails do not need to be adjusted with respect to 
each other for the installation in rack systems with 735 mm installation depth.
Ê
Secure the support systems as described in section 
.
Ê
Mount the server (see 
) and route the 
cables as described in the original manual of the rack.
V
CAUTION!
Ensure that the safety lock has been inserted before the server is 
inserted (see 
Racks with installation depth smaller/greater than 735 mm
The support systems can be used for installation depths of 714 - 785 mm. The 
spring element of the support system is used to adjust the length as required.
Ê
Secure the support systems as described in 
Ê
Mount the server (see 
) and route the 
cables as described in the original manual of the rack.
V
CAUTION!
Ensure that the safety lock has been inserted before the server is 
inserted (see