Página de 285
CHAPTER 4 PCI Card Hot Maintenance in Red Hat Enterprise Linux 6 
4.6 Hot Replacement of PCI Express Cards 
81 
 
C122-E175-01EN 
 
There are two ways to perform PCI hot plug: 
Operation by using sysfs 
Operation by using dp commands 
You can perform the operation by using dp commands if Dynamic Reconfiguration utility is installed in the 
partition. If not, be sure to use the operation by using sysfs. Although you can perform the operation by using 
sysfs even if Dynamic Reconfiguration utility is installed in the partition, it is recommended to perform the 
operation by using dp commands to prevent wrong operation. 
Hereafter, description about the operation by using dp commands starts at ‘For the partition with Dynamic 
Reconfiguration utility installed’ and description about the operation by sysfs starts at ‘For the partition without 
Dynamic Reconfiguration utility installed’. 
Notes 
If you replace PCI Express cards on an IOU, see ‘
’. 
Remarks 
For details on the card replacement procedures not described in this chapter, see the respective product 
manuals. 
4.6.1  Overview of common replacement procedures for PCI Express 
cards 
 
This section provides an overview of common replacement procedures for all PCI Express cards. 
1.  Performing the required operating system and software operations depending on the PCI Express card 
type 
2.  Powering off a PCI slot 
3.  Replacing a PCI card 
This step is performed by the field engineer in charge of your system. 
4.  Powering on a PCI slot 
5.  Performing the required operating system and software operations depending on the PCI card type 
Note 
This chapter provides instructions (e.g., commands, configuration file editing) for the operating system and 
subsystems. Be sure to refer to the respective product manuals to confirm the command syntax and impact 
on the system before performing tasks with those instructions. 
The following sections describe card addition, removal, and replacement with the required instructions (e.g., 
commands, configuration file editing) for the operating system and subsystems, together with the actual 
hardware operations. Step 3 is performed by the field engineer in charge of your system. 
4.6.2  PCI Express card replacement procedure in detail 
This section describes how to replace a PCI Express card. 
Preparing the software using a PCI Express card 
When a PCI Express card is replaced or removed, there must be no software using the PCI Express card. 
For this reason, before replacing the PCI Express card, stop the software using the PCI Express card or 
make the software operations inapplicable. 
Confirming the slot number of a PCI Express slot 
When replacing, adding or removing a PCI Express card, you need to manipulate the power supply to the 
appropriate slot, through the operating system. First, use the following procedure to obtain the slot number 
from the mounting location of the PCI Express slot for the card. It will be used to manipulate the power supply. 
1.  Identify the mounting location of the PCI Express card to be replaced. 
See the figure in 
 
to check the mounting location 
(board and slot) of the PCI Express card to be replaced. 
2.  Obtain the slot number of the mounting location. 
Check the table in 
, and 
obtain the slot number that is unique in the cabinet and assigned to the confirmed mounting locations.