Fujitsu 2000 SERIES Manual Do Utilizador

Página de 285
CHAPTER 6 PCI Express card Hot Maintenance in Windows 
6.4 FC Card Hot Plugging 
139 
 
C122-E175-01EN 
 
In case of using SVagent, “Source:SVagent, ID: 25004 Error massage” is logged in SEL when replacing, 
it is no problem. 
6.4.1  Hot plugging an FC card incorporated with the ETERNUS 
multipath driver 
This section describes the hot plugging procedure for an FC card incorporated with the ETERNUS multipath 
driver. 
1.  Confirm physical location, segment number and bus number of target NIC. 
Confirm the physical location, segment number and bus number with step 1 at ‘
Note 
In case of multi-function card, there are some cards that have same segment number, same bus number, 
and different function numbers. 
In this case, please perform Step.2 to Step.6 of follows respectively. 
2.  Confirm target device by using administration manager of the FC card, and confirm WWN, port number, 
and firmware version. 
Case: Emulex FC card 
a  Open OneCommand Manager, confirm target device with step 2. 
Select Port WWN as the same type of target FC card in left pane, and select [Port Information] tab in 
right pane. 
See “PCI Bus Number” in [Port Attributes], and look for the device which has same bus number you 
confirmed in step 1. 
 
b  See WWN and port number of target device. 
Select Port WWN of target FC card in left pane, and select [port Information] tab in right pane. WWN 
is written at “Port WWN” in [Port Attributes].