CHAPTER 10 Error Notification and Maintenance (Contents, Methods, and Procedures) 
10.1 Maintenance 
173 
 
C122-E175-01EN 
 
TABLE 10.1 Maintenance modes 
Mode 
Meaning 
Operation 
[Normal operation] 
Normal operation 
Hot System Maintenance 
[Active for work (system)] 
For maintenance work performed while the system 
power is on 
Hot Partition Maintenance 
[Active for work (partition)] 
For maintenance work performed while the target 
partition power is on 
Warm System Power Off 
[Partition stopped for maintenance] 
For maintenance work performed while the system 
power is on and the maintenance target partition 
power is off 
Cold System Maintenance (breaker on) 
[Stopped for work (standby)] 
For maintenance work performed while the system 
power is off and the AC power supply is on 
Cold System Maintenance (breaker off) 
[Stopped for work (AC off)] 
For maintenance work performed while the system 
power is off and the AC power supply is off 
TABLE 10.2 Maintenance mode functions 
Item 
Operation 
mode 
Maintenance mode 
Hot System 
Hot 
Partition 
Warm 
System 
Cold 
System 
(breaker 
on) 
Cold 
System 
(breaker 
off) 
Power 
supply 
operatio
Administr
ator 
Permitted 
Permitted 
Suppressed 
(*1) 
Suppressed 
(*1) 
Suppressed 
Suppressed 
Field 
engineer 
Suppressed 
Suppressed 
Permitted 
(*1) 
Permitted 
(*1) 
Permitted 
Permitted 
Wake On LAN 
(WOL) 
Permitted 
Permitted 
Suppressed 
(*1) 
Suppressed 
(*1) 
Suppressed 
Suppressed 
Calendar function 
Permitted 
Permitted 
Suppressed 
(*1) 
Suppressed 
(*1) 
Suppressed 
Suppressed 
OS boot 
Permitted 
Permitted 
Suppressed 
Stops at 
BIOS 
(*1) 
Suppressed 
Stops at 
BIOS 
(*1) 
Suppressed 
Stops at 
BIOS 
(*1) 
Suppressed 
Stops at 
BIOS 
REMCS report 
Permitted 
Suppressed 
(*2) 
Suppressed 
(*1) 
Suppressed 
(*1) 
Suppressed 
Suppressed 
DR function 
Permitted 
Suppressed 
Suppressed 
(*1) 
Suppressed 
(*1) 
Suppressed 
Suppressed 
*1 This pertains only to the maintenance target partition. 
*2 Suppresses the REMCS report upon system failure (but reports partition failures). 
10.1.4 Maintenance of the MMB 
If the server with single MMB fails in MMB, take actions below.   
1.  Shut down the operating system (LAN) from a remote terminal. (*1) 
2.  Turn off the chassis AC power. 
3.  Replace the MMB. 
4.  Turn on the chassis AC power. 
(*1) If you use only port of MMB to login the operating system, it is recommended to duplicate MMB. If MMB 
fails, you cannot login to the operating system. 
Remarks 
In a single MMB configuration, hot replacement of the MMB is not possible. 
10.1.5 Maintenance of the PCI_BOX (PEXU) 
The following concerning maintenance when PCI box (PEXU). 
1.  The system administrator stops all partitions that belong to the maintenance object.