CHAPTER 3 Component Configuration and Replacement (Add, Remove) 
3.2 High availability configuration 
41 
 
C122-E175-01EN 
 
FIGURE 3.12 
Example 
6. Example where a Reserved SB has been set in SB #0 (When the Home SB has failed
)  
 
 
No. 
Description 
(1) 
Since Partition #0 is the configuration of SB #0 and SB 
#2,  SB #0 with the lowest number becomes the Home 
SB.  
FIGURE 3.13 
Example 
7.  Example when SB #0 is set as the Reserved SB (
when an SB other than the 
Home SB 
fails
)
 
 
 
No. 
Description 
(1) 
The Home SB does not change when an SB other than 
the Home fails. 
Switching policy  
The triggers for switching to a Reserved SB are as follows. 
Furthermore, the timing for switching to the Reserved SB is when the partition is started up.  
This section describes the conditions (triggers) for switching to the Reserved SB when the partition is started 
up.  
SB degradation  
DIMM degradation (even in a single DIMM degradation)  
When a Memory Mirror collapse is detected 
When a QPI Lane degradation is detected 
When an SMI2 Lane switching to is detected 
When a PCI Express Lane/Speed degradation on a SB is detected 
When a CPU core degradation is detected  
Remarks  
Set a value which is not 0 in [Number of Restart Tries] of the [ASR Control] window, as the frequency of 
automatic partition restart for switching to the Reserved SB. 
For details on the [ASR Control] window, see 
  
Active Reserved SB switching process 
The process of switching of the Active Reserved SB (*1) is described in this section.