Quatech HD500 Manual Do Utilizador

Página de 135
Quatech, Inc. 
 
AirborneDirect™ User Manual
 
 
134
 
2/21/2011 
100-8510-110 
26.0  Physical & Environmental Approvals  
The device has passed the following primary physical and environmental tests. The test 
methods referenced are defined in SAE J1455 Aug1994. 
Table 49 - Mechanical Approvals 
Test 
Reference 
Conditions 
Temperature Range 
(Operational) 
Table 1B, Type 2b 
-40°C to +85°C 
Temperature Range (Non-
Operational) 
 
-50°C to +125°C 
Humidity 
Sect 4.2.3 
0-95%RH @ 38°C condensing 
Fig 4a – 8 hours active humidity cycle 
Altitude 
Sect 4.8 
Operational: 0-12,000ft (62 KPa absolute pressure) 
Non-operational: 0-40,000ft (18.6 KPa absolute 
pressure) 
Vibration 
Sect 4.9 
Operational: 2.4 Grms, 10-1K Hz, 1hr per axis  
Non-operational: 5.2 Grms, 10-1K Hz, 1hr per axis 
Shock 
Sect 4.10 
Operational: 20Gs MAX, 11ms half-sine pulse 
Product Drop 
Sect 4.10.3.1 
1m onto concrete, any face or corner, 1 drop 
Packaging Drop 
Sect 4.10.2.1 
32 inches onto concrete on each face and corner. 
Packaged in ‘for transit’ configuration. 
Test reports are available from Quatech Technical Support, please contact directly for the 