Quatech HD500 Manual Do Utilizador

Página de 135
AirborneDirect™ Users Guide
 
 
Quatech, Inc. 
100-8510-110 
2/21/2011 
19 
Table 2 - Serial Ports by Product Class 
Device Class 
Port 1 
Port 2 
Enterprise 
RS232 
RS422 (4-wire) 
RS485 (2-wire) 
N/A 
Industrial 
RS232 
RS422 (4-wire) 
RS485(2-wire) 
N/A 
RS232 
RS422 (4-wire) 
RS485(2-wire) 
RS232 
RS422 (4-wire) 
The Port 1 and Port 2 interfaces support the following configurations: 
 
BAUD: 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 
57600, 115200, 230400, 460800, 921600
 
 
Flow Control: None, Hardware (CTS/RTS), Software (XON/XOFF)
 
 
Port 1 Default settings: 9600, 8, N, 1, No Flow Control.
 
 
Port 2 Default settings: 9600, 8, N, 1, No Flow Control.
 
6.2 
Ethernet Port 
The AirborneDirect
™ Ethernet devices support a single interface. This is a 
10/100Mbps interface that supports auto negotiation and cross-over cabling. The 
interface also supports both half and full duplex for 10Mbps and 100Mbps. Table 
XX shows the interface pin out. 
Figure 7 - Ethernet Jack Pin Out 
 
Table 3 - Ethernet Connector Pin Out 
Pin 
RJ45 Socket (Industrial) 
RJ45 Plug (Enterprise) 
TxD+ 
RxD+ 
TxD- 
RxD- 
RxD+ 
TxD+ 
NC 
NC 
NC 
NC 
RxD- 
TxD- 
NC 
NC