15-26   Vol. 3
MACHINE-CHECK ARCHITECTURE
IA32_MCi_STATUS register. Recovery actions for SRAO errors are MCA error code 
specific. The MISCV and the ADDRV flags in the IA32_MCi_STATUS register are 
set when the additional error information is available from the IA32_MCi_MISC 
and the IA32_MCi_ADDR registers. System software needs to inspect the MCA 
error code fields in the IA32_MCi_STATUS register to identify the specific 
recovery action for a given SRAO error. If MISCV and ADDRV are not set, it is 
recommended that no system software error recovery be performed however, 
you can resume execution.
software recoverable action required (SRAR) - a UCR error that requires system 
software to take a recovery action on this processor before scheduling another 
stream of execution on this processor. SRAR errors indicate that the error was 
detected and raised at the point of the consumption in the execution flow. An 
SRAR error is indicated with UC=1, PCC=0, S=1, EN=1 and AR=1 in the 
IA32_MCi_STATUS register. Recovery actions are MCA error code specific. The 
MISCV and the ADDRV flags in the IA32_MCi_STATUS register are set when the 
additional error information is available from the IA32_MCi_MISC and the 
IA32_MCi_ADDR registers. System software needs to inspect the MCA error code 
fields in the IA32_MCi_STATUS register to identify the specific recovery action for 
a given SRAR error. If MISCV and ADDRV are not set, it is recommended that 
system software shutdown the system.
Table 15-6 summarizes UCR, corrected, and uncorrected errors. 
Table 15-6.  MC Error Classifications
Type of Error
1
NOTES:
1. VAL=1, EN=1 for UC=1 errors; OVER=0 for UC=1 and PCC=0 errors SRAR, SRAO and UCNA errors 
are supported by the processor only when IA32_MCG_CAP[24] (MCG_SER_P) is set. 
UC PCC S AR Signaling Software Action
Example
Uncorrected Error 
(UC)
1
1
x x
MCE
Reset the system
SRAR
1
0
1 1
MCE
For known MCACOD, take 
specific recovery action;
For unknown MCACOD, 
must bugcheck
Cache to 
processor load 
error
SRAO
1
0
1 0
MCE 
For known MCACOD, take 
specific recovery action;
For unknown MCACOD, 
OK to keep the system 
running
Patrol scrub and 
explicit writeback 
poison errors
UCNA
1
0
0 0
CMC
Log the error and Ok to 
keep the system running
Poison detection 
error
Corrected Error (CE) 0
0
x x
CMC
Log the error and no 
corrective action 
required
ECC in caches and 
memory